Compressor Specifications

Model SHP-50

Power Supply

220V~50Hz

Circuit Fuse - Model Number

30A 250VAC fast-acting cartridge fuse

Circuit Fuse - Parameters

32A/250V

Rated HP heating capacity*

5000

HP heating rated input

Power (watts)

1280

Current (amps)

6.1

Auxiliary heating input (In Tank)

Power (watts)

3600

Current (amps)

16.5

Maximum input

Power (watts)

5630

Current (amps)

26

Nominal water temperature setting (oC)

50

Max water temperature setting (oC)

60

Suitable ambient temperature (oC)

-7 ~ 43

Refrigerant charge quantity (grams)

R134a / 800

Noise Level (dBA)

≤ 48

Mass weight (kg)

58

Cold/hot water connection

RP ¾” / DN20

Dimension (mm)

A

850

B

820

C

320

D

613

 

Tank Specifications

Model SHP270-207 SHP320-207 SHP420-207 SHP495-207

Tank Capacity (L)

270

320

420

495

Electric Element (W)

3600

Nominal current (A)

16.5

Power supply

220V ~ 50Hz

Thermostat Setting (°C)

70℃ Max

Net Weight (kg)

72

83

107

115

Dimension (mm)

A

1529

1759

1930

1911

B

1320

1550

1710

1635

C

70

70

70

98

D

611

611

648

681

E

144

144

144

227

F

250

250

250

250

H

644

644

682

715

I

190

190

190

218

J

800

800

800

828

TPR Connection

RP3/4   DN20

Inlet/Outlet Water Connections

RP3/4   DN20

Circulation Water Connections

RP3/4   DN20

TPR Valve Rated Pressure (kPa)

850

Maximum Water Supply Pressure (kPa)

680

*Rating condition: Dry bulb temperature: 20°C, Wet bulb Temperature: 15°C, Tank water inlet: 15°C, Tank water outlet: 55°C.