Sunheat 150BPT
Solahart Sunheat Series is an Australian designed solar water heater specifically developed to provide hot water free from the sun in medium to high solar gain areas. The black polyester powder-coated aluminium absorber collects the sun’s heat and transfers it to the water in the copper risers. The increase in temperature causes the water to rise and move into the storage tank where it displaces cooler water. This cooler water then travels back into the solar collectors to be heated by the sun.
Key Features
The tank features Solahart Super-Shield™ enamel for enhanced protection, as well as a protective sacrificial anode to improve the life of the tank.
The Sunheat Series also utilises Solahart flat plate collector technology. This results in extra-strong glass that is resistant to breaking. Flat plate collectors provide a stronger, safer application when installed on your roof and give greater durability and sustainability than evacuated tubes.
Optimal Performance
Most suitable for areas that receive medium to high levels of solar radiation, and is suitable for frost prone or harsh water chemistry areas.Ceramic Lined Tank
Corrosion protection for the water heater’s solar tank is achieved by using a proven, high quality vitreous enamel lining on the tank. Additional protection is gained by the use of a sacrificial anode.
Booster Options
The electric boosted models are equipped with an in-tank element.Environmental Incentives
Switch to a Solahart solar water heater and save up to 2.7 tonnes of carbon emissions per year, which is equivalent to taking a small car off the road.-
Specifications
Tank Model - 150L Tank Storage Capacity (L) 150 Boost Capacity (Electric) (L) 75 Weight Empty (kg) 44 Weight Full (kg) 194 A-Width* (m) 1.66 B-Length* (m) 0.45 Tank Model - 151L System Storage Capacity (L) 150 Boost Capacity (Electric) (L) 75 Weight Empty (kg) 76 Weight Full (kg) 128 A-Width* (m) 1.66 B-Length* (m) 2.487 BPT Collectors Aperture (heating) Area (m2) 1.87 Length (mm) 1940 Width (mm) 1024 Height (mm) 80 Capacity (L) 1.5 Weight Emtpy (kg) 32 Weight Full (kg) 34 Working Pressure 1000 kPa/ 145 psi Absorber Surface Black polyester powder coat Absorber Material aluminium Riser Material copper tube Tray Material 0.7 mm aluminium Insulation Material - Base 38 mm polyester blanket Glass 3.2 mm tempered low iron glass Electric Boost Specifications Electric Boost Specifications Heating Unit Type Cooper sheath immersion element Supply Voltage 240 V -250 V Water Supply TPR Valve Setting 1000 kPa / 145 psi ECV* Setting 850 kPa / 125 psi Max. Supply Pressure With ECV (kPa) 680 Max. Supply Pressure Without ECV (kPa) 800 Water Connections Cold DN15 compression fitting Water Connections Hot R 1/2 -
How it works
How Roof Top Solar Systems Work - Solar Operation
The 181L solar system has its vitreous enamel lined solar storage tank installed on the roof directly coupled to the solar collectors. It works on the simple scientific fact that hot water rises. As the sun heats the water in the solar collectors, the increase in temperature causes the water to rise through an insulated copper pipe into the storage tank. This allows cooler water from the solar storage tank to flow into the solar collectors to be heated by the sun‟s energy. This process continues while solar energy is available.
Orientation of Solar Collectors
To help maximise system performance, solar collectors should be installed with an optimum orientation facing true north (in the southern hemisphere) or true south (in the northern hemisphere). Always check for true north or true south using a compass or other suitable device.
To help maximise system performance, solar collectors should be installed with an optimum inclination. This is equal to 90% to 100% of the local latitude angle when collectors are oriented within 60° of true north or true south, and between 10° and 20° if the collectors are oriented between 60° and 90° from the optimum orientation. Generally, improved summer performance is obtained from an angle of inclination less than the optimum angle and improved winter performance is obtained by an angle of inclination greater than the optimum angle. If the angle of inclination varies by 20° from the optimum angle, the solar collectors will receive about 10% less total annual solar radiation.
Solar Boosting - In-Tank Boosting
An isolating switch is installed in the electrical meter box for an electrically in-tank boosted model. This should be left switched on to allow the booster heating unit to operate if required. The booster heating unit is for heating the water at times of low solar energy gain, such as during very cloudy or rainy weather, or during the colder months. The booster heating unit will only activate if heating is required and power is available from the switchboard. When the water is below the thermostat setting, the booster heating unit will turn on and heat the water. The booster heating unit will automatically turn off when the temperature of the water reaches the thermostat setting. If the water temperature drops below the setting again the booster will re-activate.
- Downloads